Chapter 7 Maintenance

Screw section

Hole

Hole

Set screw Processor rail (left)

Exit roller (upper)

Rinse water nip roller

4)Attach the supply pipe to the processing chemical supply hose.

5)Install the processing chemical supply pipe.

Caution

When the processing

 

chemical supply pipe is

 

clogged, clean the pipe

 

regardless of the time

 

elapsed.

Cleaning the nip roller and exit roller

(upper)

Note

Always clean the rinse water

 

 

nip roller and upper exit roller

after processing 1000 plates or every month.

1)Loosen the set screw (with a coin) to remove the left processor rail.

2)Pull out the left processor rail toward the operator side.

3)Lift up and remove the rinse water nip roller.

Caution

The rinse water nip roller weighs approximately 2 kilograms, so please

 

be very careful when handling it.