Chapter 7 Maintenance

Diffusion sheet

Brush bar

Diffusion sheet

SLM-EAC

SLM-EST

Note

If the diffusion sheet is curved or bent, loosen the sheet retainer on the processing chemical supply guide and replace the sheet with a stand-ard diffusion sheet.

9)Wash the processing chemical supply guide diffusion sheets (SLM-EAC x 2, SLM-EST x 1) with water and wipe them dry with a clean cloth.

10)Wash the processor rack and overflow tray with water.

Note

The synthetic rubber used for the processor rack roller is susceptible to high temperatures, so don't wash it with water that is warmer than 40˚C. Never use detergent or other cleaning solutions.

11)Re-attach the supply guides to the processor rack.

Cleaning the processing chemical tank and filter

Note

Upper cover

Always clean the processing chemical tank and filter when you replace the processing chemical every three months or after processing 1000m2 of plates.

1) Lift the upper cover for the processing tank and pull out the tank.

Processing tank

- The upper cover for SLM-EAC is attached to a panel heater, so it

Caution may be very hot. Be very careful when performing this operation.

- Sensor cords are connected to the upper cover. Do not forcibly pull at these cords.

- 53 -

Page 61
Image 61
Mitsubishi Electronics SDP-ECO 1630 III manual Re-attach the supply guides to the processor rack