Chapter 7 Maintenance
•Resetting the punch counter
1) Pressing the MENU key bring up the < Plate Data > window on the display panel.
2)Press the key to select the <MODE> and then Press the key.
3)Press the key when PUNCH DRYER > is displayed.
4)When <MODE> is displayed, press the key to bring up the < COUNT••••CLR display and then select CLR.
5)Press the key resets the punch counter.
7.5Cleaning the processor section
After repeated prepress operations, silver residue from plates, paper dust, chemicals, etc. may stick to the tank and/or processor rack, and stain subsequent separations.
Note
-Always clean the sections shown below when you replace the processing chemical every three months.
-Always follow the procedures in "4.9 Turning OFF the power supply and inspection at shutdown" on page 34 before shutting down the machine.
Caution
You must thoroughly read "1.3 Handling processing chemicals".
•Cleaning the processor rack
1) Turn OFF the main power switch.
2) Lay out the maintenance mat.
3) Open the front door and remove the replenisher bottle.
Replenisher bottle
Maintenance mat
|
|
| 4) Discard the | |
|
|
| ||
|
|
| cal tank. | |
|
|
| 5) Hold the handle for the processor | |
|
|
| rack section and pull out the | |
|
|
| processor rack until it touches the | |
|
| |||
waste | Waste chemical tank | stopper. | ||
chemical | ||||
waste |
| |||
hose |
|
| ||
chemical |
|
| ||
|
|
| ||
| hose |
|
| |
|
|
|