Chapter 4 Operation

4.6 Exposure

The machine has two exposure modes: remote exposure which performs exposure using data provided from the host computer, and local exposure which performs laser test exposure and re-exposure.

Remote exposure

After entering remote mode (ON LINE lamp is lit), give the exposure command through the host computer (RIP computer). While exposure is in progress, "Exposing ***%" is displayed on the panel display. "***%" indicates the percentage currently exposed.

[Display during remote exposure]

The panel display changes as shown below during the exposure.

Data transmission start Data transmission end

Data Transferring

Image data exposure start

Exposing 0%

Image data exposure end

Exposing 100%

Plate is being discharged

Discharging

Completion

Complete

Local exposure

[Laser Test Expo.]

(1) Confirmation and input of the plate type, resolution and light intensity

1)

Use the MENU

key to call up

 

< Plate Data >

 

display.

2)

Select <Laser> using the

key and press the ￿￿￿￿key.

3)

Press the

￿￿￿￿

key while

Laser Test Expo.

is displayed.

4)

Plate type, resolution and light intensity are displayed.

 

(Example)

 

 

 

 

(F175 1200 dpi Light intensity 200)

 

￿￿￿￿F 1 7 5 ( 1 2 ) 2 0 0

 

 

 

 

 

 

 

5)Press￿￿￿￿the key to change the resolution. Select the desired resolution from among 12 (1200 dpi), 15 (1500 dpi), 18 (1800 dpi) and 24(2400dpi) using the ￿￿￿￿ key. Register the resolution using

the key.

6)Press the ￿￿￿￿ key to move the cursor to the light intensity value

display and then press the key.

7)Change the light intensity value using the key or the key.

Press the key to register the light intensity value.

Note

Press the MENU key to return to the previous menu if no change is necessary or setting is discontinued.