3460 Fast’R

Options Stored in Status (S-) Registers

Some AT command options are stored in status registers.

S-Register Command Cross-Reference

 

 

Command

 

 

 

 

(Default

 

 

Register

Parameter

Value)

 

Description

 

 

 

 

S0

Ring Count to

ATS0=n

Modem answers a call after ring n

 

Answer On*

(0)

 

 

S1

Current Ring

ATS1

Counts rings (view only)

 

Count*

(0)

 

 

 

 

 

 

S2

Escape Code

ATS2=x

Defines character used to change

 

Character*

(43)

from data mode to command

 

 

 

mode.

 

 

 

 

S3

Return

ATS3=x

Set command-line termination

 

Character*

(13)

character

 

 

 

 

S4

Line Feed

ATS4=x

Set response formatting character

 

Character*

(10)

 

 

 

 

 

 

S5

Backspace

ATS5=x

Set command-line editing

 

Character*

(8)

character

 

 

 

 

S6

Wait For Dial Tone

ATS6=n

Set duration

 

 

(3)

 

 

 

 

 

 

S7

Wait For Data

ATS7=n

Set duration

 

Carrier

AT*DD9

Dial Wait=S7

 

(Country-specific

AT*TT5

Call Timeout=S7

 

for France only)

(30)

 

 

 

 

 

 

S8

Dial Modifiers

ATS0=x

Set comma character

 

 

(3)

 

 

 

 

 

 

S10

DCD Loss

ATS10=n

Set delay duration; varies with the

 

Disconnect

(15)

modulation mode:

 

 

 

• V.34, V.32:

 

 

 

0=Disabled

 

 

 

1-19=Specified sec.

 

 

 

20-255=20 sec.

 

 

 

• V.22bis, V.21, B212, B103:

 

 

 

0=Disabled

 

 

 

1-255=Specified 0.1 sec

 

 

 

 

 

*Changed values are not automatically stored to non-volatile memory. To retain changed values, save them to an option set.

B-31

Page 141
Image 141
Motorola 3460 manual Options Stored in Status S- Registers, Command Default Register Parameter Value Description