Programming Model

Scrub Timer Counter (Bits 7-0)

This register reflects the current value in the Scrub Timer counter bits 7-0.

ADR/SIZ

 

 

1st $FFF43048/2nd $FFF43148 (8-bits)

 

BIT

31

30

29

28

27

26

25

24

NAME

ST7

ST6

ST5

ST4

ST3

ST2

ST1

4

ST0

OPER

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

RESET

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

Scrub Address Counter (Bits 26-24)

This read/write register is the Scrub Address counter. Each time the scrubber performs a scrub memory cycle, the Scrub Address counter increments. For an entire scrub, the Scrub Address counter starts at 0 and increments until it reaches the DRAM size that is indicated by the MEMSIZ pins. Writes to this address update the Scrub Address counter; reads to this address yield the value in the counter. The ability to read and write this counter is provided for test purposes. Note that if scrubbing is in process, the Scrub Time On/Time Off register should be set for the minimum time on and the maximum time off during any writes to this register. This register reflects the current value in the Scrub Address counter bits 26-24.

ADR/SIZ

 

 

1st $FFF4304C/2nd $FFF4314C (8-bits)

 

 

 

 

 

 

 

 

 

 

 

BIT

31

30

 

29

28

27

26

25

24

 

 

 

 

 

 

 

 

 

 

NAME

0

0

 

0

0

0

SAC26

SAC25

SAC24

 

 

 

 

 

 

 

 

 

 

OPER

R/W

R/W

 

R/W

R/W

R/W

R/W

R/W

R/W

 

 

 

 

 

 

 

 

 

 

RESET

X

X

 

X

X

X

0 PLS

0 PLS

0 PLS

 

 

 

 

 

 

 

 

 

 