9.Ensure that the zero-fill stops after one pass by clearing the SCRBEN bit in the Scrub Control register. (Clear bit 27 of offset $24.)

10.Wait for the zero-fill to complete by waiting for the SCRB bit in the Scrub Control register to be cleared. (Wait for bit 28 of offset $24 = 0.)

11.Clear the ZFILL bit in the MCECC pair. (Clear Bit 28 of offset $20.)

12.The entire DRAM that is controlled by this MCECC is now zero- filled. The software can now program the appropriate scrubbing mode and other desired initialization, and enable DRAM for operation.

4