NEC LC1400 manual RAID Configuration

Models: LC1400

1 200
Download 200 pages 1.21 Kb
Page 144
Image 144

RAID Configuration

The RAID options available for your system are the Mylex AcceleRAID150 and the Mylex AcceleRAID 250 Controller boards, which gives your system the added security of fault tolerance.

If you order a system with a RAID controller, the system is pre-cabled at the factory (see "RAID System Cabling Configuration" figures below.)

If you are adding either the AcceleRAID150 or the AcceleRAID 250 Controller you must install, cable, and configure the controller. Refer to "Installing a RAID Controller Board" in Chapter 4.

Note: Next Boot Status for the first Symbios SYM53C875 controller must be turned OFF if you install the optional Mylex AcceleRAID150 or Mylex AcceleRAID 250 Controller board in your system. Refer to “Symbios Configuration Utility” found in Chapter 3.

Note that Jumper JP10 (see figure below) that enables the SCSI Interrupt Steering Logic (SISL) control on the RAID controller must be in its off position (not jumpered), which is its default position.

Note: The jumper is set correctly at the factory for your system configuration. If your system requires a jumper change, change only the jumper setting for that condition. Otherwise, keep the jumper at its factory setting.

A-6 System Cabling