SEL Viewer Menu Options
The following menu options are found on the SEL viewer menu bar:
nFile
⎯Open - you can view SEL data from a previously saved file if it was stored in binary format. Selecting the Open menu item allows you to specify a filename under which the data is found. The default filename is "SELLOG.DAT." If the file cannot be opened, the program displays an error message.
⎯Close - you can close the SEL viewer.
⎯Save As - dumps the SEL data to a file in either binary raw or verbose text format. The binary file may be retrieved later. Selecting this option lets you specify a filename to which the data would be saved. The default filename is "SELLOG.DAT." If there is no data, an error message will be displayed.
⎯Exit - exits the EMP.
nConnect
nView
⎯SEL Information - displays SEL summary information as returned by the server.
⎯All Events - displays all events in the SEL.
⎯By Sensor Type - shows all events in the SEL generated by a specific sensor type such as voltage, temperature, etc.
⎯By Event - displays all the events in the SEL of a particular type; for example, by memory or threshold. A
nSettings - you can change several operating parameters for the SEL viewer. This menu displays the following suboptions:
⎯Display HEX/Verbose - toggles between HEX mode and interpreted mode of displaying SEL records.
⎯Output Text/Binary - determines whether SEL data will be saved to the file in binary format or verbose format.
nWindow - gives options for displaying currently open windows.
nHelp - provides version information for the SEL viewer and provides help topics on the EMP.