NEC LC1400 manual Sensor Type Codes, Using the Sensor Type Code Table

Models: LC1400

1 200
Download 200 pages 1.21 Kb
Page 177
Image 177

Sensor Type Codes

The Sensor Type Code Table provides information regarding:

nThe type of sensor generating the SEL entry

nThe name of the sensor

nThe microcontroller which initiated the SEL entry

nThe warning or error which initiated the SEL entry.

Using the Sensor Type Code Table

Compare the Sensor Type and Number message shown in the SEL viewer display (above) to the Sensor Type/Number in Verbose column in the table below. Using information in the Sensor Name column in the table you can determine the physical component which generated the SEL message. The Generator ID column in the table identifies the microcontroller which reported the event to the SEL. Detailed information regarding the event is available from the Event Description column in the SEL Viewer.

For example, if there is a Fan #10 entry in the Sensor Type and Number column of the SEL Viewer, by looking at the Sensor type Codes table you can determine that the Baseboard Fan 1 caused this entry. The entry was reported through the Baseboard Management Controller (BMC) on the system board.

Sensor Type Codes

Sensor Type and Number in

 

 

Verbose

Sensor Name

Generator ID

 

 

 

Reserved

00h

BMC

 

 

 

Temperature #17

Processor1 Temp

BMC

 

 

 

Temperature #18

Processor2 Temp*

BMC

 

 

 

Temperature #19

Baseboard Temp1

BMC

 

 

 

Temperature #1A

Baseboard Temp2

BMC

 

 

 

Voltage # 01

Baseboard 5V

BMC

 

 

 

Voltage # 02

Baseboard 3.3V

BMC

 

 

 

Voltage # 03

Primary Processor

BMC

 

 

 

Voltage # 04

Secondary Processor*

BMC

 

 

 

Voltage # 05

Processor 2.5V

BMC

 

 

 

*Not applicable to all servers

 

 

Emergency Management Port Console C-15

Page 177
Image 177
NEC LC1400 manual Sensor Type Codes, Using the Sensor Type Code Table, Emergency Management Port Console C-15