NAP-200-010

Sheet 7/7

System Initialization and System Data Entry

A

CM35

DESCRIPTION

 

 

DATA

Assign the type of signaling (DTMF) for Outgoing

.

YY = 01

and Bothway Trunk Routes.

(1)

Trunk Route No. (00 - 63)

 

(2)

7

Specify the DTMF Sender characteristics to match

.

YY = 24 (DTMF Inter Digital Pause)

the distant office.

(1)

Trunk Route No. (00 - 63)

CM08

0

: 32ms

1

: 64ms

2

: 80ms

3

: 96ms

4

: 160ms

5

: 192ms

6

: 240ms

7

: 128ms

.

YY = 26

(DTMF Sender Signal Width)

(1)

Trunk Route No. (00 - 63)

(2)

0/1 : 64ms/128ms

.

YY = 46

(DTMF Sender Release Timing)

(1)

Trunk Route No. (00 - 63)

0

: 2sec.

1

: 4sec.

2

: 6sec.

3

: 8sec.

4

: 12sec.

5

: 14sec.

6

: 16sec.

7

: 10sec.

Assign whether “*” or “#” from a DTMF Telephone

(1)

050 (* is used as Switch Hook Flash)

is used as Switch Hook Flash while hearing Busy

(2)

0: Available

Tone.

(1)

052 (# is used as Switch Hook Flash)

 

(2)

0: Available

END