| Table | Functional Outline of Line/Trunk Circuit Cards (Continued) | |
|
|
| |
CARD NAME | FUNCTIONAL | FUNCTIONAL OUTLINE | |
NAME |
| ||
|
|
| |
|
|
|
|
| DIT |
| |
|
|
| This card is equipped with the function for loop detection, sending reverse signal and |
|
|
| PB to DP signal conversion. This card is internally equipped with |
|
|
| Power supply. |
|
|
|
|
| DK |
| Circuit card for External Relay Control/External Key Scan |
|
|
| This card is provided with eight circuits, and can provide the |
|
|
| functions on a per circuit basis. |
|
|
|
|
| DLC |
| |
|
|
| ElectraPro/DSS Console |
|
|
| This card is equipped with quick diagnostics to detect short line conditions and the |
|
|
| normality (Synchronous/Asynchronous) of the terminal. |
|
|
|
|
| DLC |
| |
|
|
| DESKCON |
|
|
| This card is equipped with quick diagnostics to detect short line conditions and |
|
|
| normality (Synchronous/Asynchronous) of terminal. This card is internally equipped |
|
|
| with a |
|
|
|
|
| DLC |
| |
|
|
| Console |
|
|
| This card is equipped with quick diagnostics to detect short line conditions and the |
|
|
| normality (Synchronous/Asynchronous) of the terminal. This card is internally |
|
|
| equipped with |
|
|
|
|
| DLC |
| |
|
|
| III/DSS Console/DESKCON |
|
|
| This card is equipped with quick diagnostics to detect short line conditions and the |
|
|
| normality (Synchronous/Asynchronous) of the terminal. |
|
|
|
|
| DLC |
| |
|
|
| Console |
|
|
| This card is equipped with quick diagnostics to detect short line conditions. |
|
|
|
|
| DLC |
| |
|
|
| DESKCON |
|
|
|
|
| DPC |
| |
|
|
| This card is used for the |
|
|
| path connection. This card can accommodate a maximum of two DTE with V.11 (X.21) |
|
|
| interface or V.24/V.28 |
|
|
|
|
| ILC |
| |
|
|
| This card provides a physical interface to ISDN Terminals. |
|
|
|
|
| LC |
| |
|
|
| Loop resistance: Max. 600 ohms |
|
|
| This card is equipped with the function for controlling Message Waiting Lamp. |
|
|
| Each 4 circuits are equipped with momentary open function. |
|
|
| This card is equipped with quick diagnostics to detect short and open line conditions. |
|
|
| This card is internally equipped with a +80 V |
|
|
|
|
NDA-24219 CHAPTER 2