Sheet 54/55
Termination of Cables on MDF
(15)Single Line Device Interface - Recommended Method
The NEAX1000 does not provide Ring Generator Voltage or Message Waiting light supply. An external Ring Generator may be installed, but there is no connector for interfacing a Message Waiting power supply. It is therefore recommended that single line devices be interfaced to the system via Analog Port Adapters with Ring, which are operating in Dual Port Mode. See Figure
|
|
|
|
|
|
|
|
|
| VIRTUAL SLOT LT09 |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LT | MP |
|
|
|
|
|
|
|
|
| 08 |
|
|
|
|
|
|
|
|
|
| 8 |
|
|
|
|
|
|
|
|
|
| D |
|
|
|
|
|
|
|
|
|
| L |
| P | 0051 | LEN to be used for | |||
|
|
| C |
| 0050 | station assignment | ||||
|
|
|
| W | ||||||
|
|
| Note |
| R | 0049 | of station connected | |||
|
|
|
|
| 0048 | to APR | ||||
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Dterm | ||
SINGLE LINE DEVICE | APR |
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| APR in Dual Port Mode | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| for Single Line Interface | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: When upper 4LENs of 8DLC, mounted in LT08, is used for Dual Port Mode Extension Assignment, no system ports are lost. The lower 4 LENs of Virtual Slot LT09 are used for Station Assignment of Analog Port Adapter Station.
Figure 007-42 Single Line Device Interface
NDA-24219 CHAPTER 3
Page 103
Revision 2.0