NAP-200-007
Sheet 47/55
Termination of Cables on MDF
•Figure 007-36 shows the MDF cross connection for the No. 0 circuit on the PFT (PZ-8PFTA), as an
example. |
|
|
|
|
| |
|
|
|
| MDF |
|
|
|
|
|
| Tip |
|
|
|
|
|
| Ring |
| TO C.O. LINE |
|
|
|
| Tip |
|
|
|
|
|
| Ring |
| TO STATION |
| PIM0 |
| LTC0 |
| ||
|
|
|
|
| ||
J | P |
|
| PFT0 | ||
LEN0000 | R0 | 1 | 1 | Sta. R0 | 1 |
|
T0 | 26 | 26 | Sta. T0 | 26 |
| |
(No. 0) |
| |||||
LEN0001 | R1 | 2 | 2 | 4LC. R0 | 2 |
|
T1 | 27 | 27 |
| |||
(No. 1) |
| |||||
LT01 | R2 |
| 3 | 4LC. T0 | 27 |
|
3 |
|
|
| |||
LEN0002 |
|
|
| |||
T2 | 28 | 28 |
|
| No. 0 | |
(No. 2) |
|
| ||||
LEN0003 | R3 | 4 | 4 | C.O. R0 | 3 |
|
T3 | 29 | 29 |
| |||
(No. 3) | C.O. T0 | 28 |
| |||
|
|
|
|
| ||
|
| 4COT. R0 | 4 |
| ||
LEN0008 | R0 | 9 | 9 |
| ||
4COT. T0 | 29 |
| ||||
T0 | 34 | 34 |
| |||
(No. 0) |
|
|
| |||
LEN0009 | R1 | 10 | 10 |
|
|
|
(No. 1) | T1 | 35 | 35 |
| P | J |
LT02 | R2 |
|
|
| ||
11 | 11 |
|
|
| ||
LEN0010 |
|
|
| |||
T2 | 36 | 36 |
|
|
| |
(No. 2) |
|
|
| |||
LEN0011 | R3 | 12 | 12 |
|
| PFT1 |
T3 | 37 | 37 |
|
| ||
(No. 3) |
|
| ||||
|
|
|
|
| ||
|
|
|
|
|
| |
G |
|
|
|
| 24 |
|
|
|
|
|
| 49 | E |
|
|
|
|
|
| |
|
|
|
|
| 25 |
|
|
|
|
|
| 50 | |
|
|
|
|
|
| |
|
|
|
|
| P | J |
|
|
|
| INSTALLATION CABLE |
|
|
| Figure | MDF Cross Connection for PFT | ||||
CHAPTER 3 |
|
|
|
|
| |
Page 96 |
|
|
|
|
|
|
Revision 2.0 |
|
|
|
|
|
|