Sheet 2/4
Connection of Battery
CAUTION 3: Battery Replacement Table and Battery Warnings
The label, which shows battery replacement table and battery warnings, is attached to the re- verse side of Front Cover for PIM. During the battery installation process, always observe the warning statements. When replacing batteries, adhere to the battery replacement table to in- crease battery life and to insure safe operation. See Figure
PIM
LABEL
FRONT COVER
BATTERY REPLACEMENT TABLE
INSTALLATION DATE: | , | . | |
AMBIENT | 25°C | 25°C~30°C | 30°C~40°C |
TEMPERATURE | (77° F) | (77° ~86° F) | (86° ~104° F) |
|
|
|
|
REPLACEMENT | 2.5~3.0 | 2.0~2.5 | 1.5~2.0 |
INTERVAL | YEARS | YEARS | YEARS |
|
|
|
|
•ELECTROLYTE LEAKAGE OR OTHER HAZARDS MAY RESULT IF THE BATTERY IS NOT REPLACED IN ACCORDANCE WITH THE SPECIFIED INTERVALS.
CAUTION TO PREVENT INJURY AND SKIN BURN, PAY ATTENTION TO THE FOLLOWING.
•DO NOT STRIKE A MATCH OR CAUSE A SPARK IN VICINITY OF BATTERY.
•PLACE THE EQUIPMENT IN A WELL VENTILATED AREA.
•DO NOT SHORT.
•REPLACE BATTERY ONLY AFTER BATTERY GASES HAVE BEEN DISPERSED.
Figure |
|
| CHAPTER 3 |
| Page 45 |
| Revision 2.0 |