NAP-200-005

Sheet 1/4

Connection of Battery

1. BATTERY CONNECTION

CAUTION 1: 24V batteries must be used in this system.

CAUTION 2: If battery terminals (+, –) contact with the module under connecting the battery cable to the PZ- PW86/PW112 card, the PZ-PW86/PW112 card or the BWB may be broken. Therefore, the in- staller must perform work in accordance with the following steps when mounting or removing the batteries.

When mounting batteries:

(1)Connect the battery cable to the batteries.

(2)Mount the batteries into the appointed position of the PIM.

(3)Connect the battery cable to the PZ-PW86/PW112 card.

When removing batteries:

(1)Disconnect the battery cable from the PZ-PW86/PW112 card.

(2)Remove the batteries from the PIM.

 

 

Standard Battery

 

Internal Battery

:

GS type PX 12026

 

 

 

 

 

 

 

 

 

 

 

Optional Battery

 

External Battery

:

YUASA

type

NPH-3.2-12

 

 

MATUSHITA

type

LCR-12V-3.4NE

These batteries will provide 30 minutes of battery backup. They will not fit within the NEAX1000 PIM.