Parameter 8: Discard Output
Parameter 8 specifies whether data received by the PAD from the remote end is transmitted to the local DTE device. The control of data delivery is only possible when the PAD is in data transfer mode (i.e., this is the mode when data is being delivered to the local DTE device).
Table
Value | Description |
0Normal data delivery *
1Discard output to the DTE
*default
Parameter 9: Padding after Carriage Return
|
| Parameter 9 specifies the number of padding (null) characters | |
|
| inserted after a carriage return, which is transmitted or echoed | |
|
| to the local DTE device. This provides the printing mechanism | |
|
| of the local DTE device time to physically complete the | |
|
| carriage return (advance the printing head to the beginning of | |
|
| the line). Once complete, the PAD can resume sending data to | |
|
| the local DTE device without losing data. | |
|
| Parameter 9 also applies to the number of padding characters | |
|
| inserted after the format effecter (carriage return and line feed). | |
|
| The format effecter is sent in conjunction with PAD service | |
|
| signals to the local DTE device when the PAD is in PAD | |
|
| command mode. | |
| Table | ||
|
|
|
|
Value | Description |
|
|
|
| ||
|
| ||
0 | No padding after any carriage return or the line feed of the format | ||
| effecter. * |
|
|
|
| ||
| If parameter 8 is set to 0 then: | ||
|
|
|
|
| DTE Speed |
| # of Padding Characters |
|
|
|
|
| 110 |
| 2 |
|
|
|
|
| 300 |
| 4 |
|
|
|
|
| 600 |
| 4 |
|
|
|
|
| 1200 |
| 4 |
|
|
|
|
| >1200 |
| 0 |
|
|
| |
1 to 255 | Specifies the number of padding characters | ||
|
|
|
|
* default |
|
|
|