Softload
SOFTLOAD OPERATION
|
| The softload facility in the TA supports the following |
|
| functions: set/display softload password, request softload |
|
| version information (on both active and alternate sets), initiate |
|
| softload, and swap to alternate software. |
|
| The LCD menu supports the softload operation and remains |
|
| fully operational while the softload is in progress. The status |
|
| can be displayed by selecting DIAGNOSTIC OPTIONS? and |
|
| DISPLAY STATUS SOFTLOAD?. |
|
| The status messages are shown in Table |
| Table | |
|
|
|
LCD Status Message | Description | |
|
|
|
SOFTLOAD NOT |
| The “not initiated” message will be displayed upon |
INITIATED |
| |
|
|
|
SOFTLOAD IN |
| This message will be displayed after the softload has |
PROGRESS |
| been successfully started. The message will be |
|
| displayed as long as no problems occur with the |
|
| softload. |
|
|
|
SOFTLOAD |
| This message will be displayed after the successful |
COMPLETE |
| completion of a softload. |
|
|
|
SOFTLOAD FAILED | This message will be displayed after the softload fails | |
|
| for any reason. The error code can be viewed using the |
|
| S59 command. |
|
|
|
|
| Softload operations must be initiated using the AT commands |
|
| listed in Table |
| Table | |
|
|
|
Command |
| Operation |
|
| |
%P1 | Display or set softload password | |
|
| |
$Q | Request softload version information | |
|
| |
$Y = x | Initiate softload with password x | |
|
| |
$Y2=x | Copy active Flash PROM to alternate Flash PROM | |
|
| |
$T = x | Swap to alternate software with password x | |
|
|
|
The commands are described on the following pages.
Set/Display Softload Password: %P1
A password must be entered to perform softload and swaps. The %P1 command is used to display or change the softload password. Any password changes must be made from the local DTE.
UTA220/UTA220k |