Softload
2.To be sure that the software in the file is correct, display the file on the host computer (be careful not to modify it). At the top of each file is a header (ASCII format) containing the product and version information for the softload file. If the host is a
where filename is the name of the softload file to display.
3.Load the file to be downloaded to the TA onto the host computer hard disk before downloading (this significantly decreases the download time).
4.Connect the PC to any of the TA’s DTE port(s). Begin executing the communications software package on the host.
5.Configure the host software for: 19200 bps
6.Using the terminal emulation mode on the host, send an AT command to the TA. The TA should respond with OK.
7.Configure the TA for RTS/CTS flow control, using either the keypad on the front panel or the AT&K3 command.
8.Check the version numbers of the current software on the TA to verify that it is to be downloaded into the correct alternate set. Enter AT$Q. The TA should respond with the version codes for both the active and alternate set.
9.Initiate Softload. Enter the AT$Y=x (where x is the softload password). The TA responds with either ERROR (if the password is invalid) or the softload method banner (SOFTLOAD
10.When the erase is complete, the TA returns
11.Initiate the
12.If any errors are encountered during the file transfer attempt, set the host back up for the terminal emulation mode and enter ATS59? to display the softload error code.
13.After the
ERROR.
UTA220/UTA220k |