EIA-366 Dialer Operation

Chapter 7

EIA-366 Dialer Operation

The UTA220 implements the EIA-366 dialer in accordance with the EIA Standard RS-366 specification.

CONFIGURATION

The upper two ports of the UTA220 are configured as EIA-366 dialer ports. In this configuration, the lower two ports function as the data ports for the dialer ports. The EIA-366 dialer ports are dedicated to the data ports as follows:

Dialer port 3 is dedicated to data port 1

Dialer port 4 is dedicated to data port 2

OPERATION

Calls are initiated through the parallel dialer port interface (the upper two ports).

The DTE connects to the dialer port by the DB-25 connector.

Connector functions are shown in Table 7-1.

Note: If an EIA-366A device is to be connected to a port, refer to EIA-366A Requirements section in Appendix D.

 

Table 7-1: Dial Connector Functions

 

 

 

Pin

 

Function

 

 

 

1

 

Frame Ground

 

 

 

2

 

Digit Present (DPR)

 

 

 

3

 

Abandon Call and Retry (ACR)

 

 

 

4

 

Call Request (CRQ)

 

 

 

5

 

Present Next Digit (PND)

 

 

 

6

 

Power Indication (PWI)

 

 

 

7

 

Signal Ground

 

 

 

13

 

Distant Station Connected (DSC)

 

 

 

14

 

Digit Lead 1 (NB1)

 

 

 

15

 

Digit Lead 2 (NB2)

 

 

 

16

 

Digit Lead 3 (NB4)

 

 

 

17

 

Digit Lead 4 (NB8)

 

 

 

22

 

Data Line Occupied (DLO)

 

 

 

UTA220/UTA220k

7-1

Page 61
Image 61
Northern UTA220/UTA220k manual Chapter EIA-366 Dialer Operation, Configuration, Pin Function