Table
Value | Description |
0No designated data forwarding character
2Data forwarding on carriage return *
126Data forwarding on all ASCII decimal characters from 0 to 31 and character DEL. (Refer to Appendix F)
*default
If a data forwarding character’s function is duplicated, the associated function for the character is according to following priority:
1.PAD recall
2.Command signal delimiter
3.XON and XOFF
4.Line display
5.Character delete
6.Line delete
7.Data forwarding
For example, if the character DLE is assigned to two functions data forwarding (parameter 3 = 126) and PAD recall (parameter 1 = 1), DLE is treated as the PAD recall character. The PAD recall function has higher priority than the data forwarding function. This also applies to: BS, CAN, DC1, DC2, DC3, and DC4 (refer to Appendix F).
Parameter 4: Selection of Idle Timer Delay
This parameter designates the amount of idle time (time in which a character is not received) allowed after the PAD has received a character from the local DTE device before the entire PAD buffer is forwarded. The idle timer is not started if parameter 15 is enabled. The decimal value stored in parameter 4 designates the timer value in 20ths of a second.
| Table |
|
|
Value | Description |
|
|
0 | No idle timer delay * |
|
|
1 to 255 | Specifies the timer value in 20ths of a second |
|
|
*default
UTA220/UTA220k |