Northern UTA220/UTA220k Parameter 19 Editing PAD Service Signals, PAD or parameter 6 is set to

Models: UTA220/UTA220k

1 187
Download 187 pages 21.16 Kb
Page 107
Image 107
Parameter 19: Editing PAD Service Signals

D-Channel X.25

Parameter 19: Editing PAD Service Signals

Parameter 19 specifies whether editing service signals for the character delete (parameter 16) and line delete (parameter 17) are transmitted to the local DTE, and also specifies their formats. The line display (parameter 18) service signal is transmitted to the local DTE device, regardless of the parameter 19 setting.

For different local DTE devices, different editing service signals must be transmitted to the local DTE device. For example, a display terminal can display the character delete service signal as BS SP BS, which backspaces the cursor over the character to be deleted, inserts a space, and then moves the cursor back to the deleted character position. Because a printing terminal is not capable of physically removing the character to be deleted, the character delete service signal displays as a slash (/) on the printing terminal device. If parameter 6 (control of PAD service signals) is disabled, the value of parameter 19 is ignored.

Note: None of the service signals are transmitted to the local

DTE display device if there are no characters stored by the

PAD or parameter 6 is set to 0.

 

Table 12-25: Editing PAD Service Signals

 

 

 

Value

Description

 

 

 

 

0

No editing PAD service signals. Line display service signals are

 

transmitted to the DTE

 

 

 

1

For edit character, the corresponding service signal is transmitted to

 

the DTE printing device:

 

 

 

 

 

Edit Character

Service Signal

 

 

 

 

Character Delete

/

 

 

 

 

Line Delete

XXX CR LF

 

 

 

2

For edit character, the corresponding service signal is transmitted to

 

the DTE display device: *

 

 

 

 

 

Edit Character

Service Signal

 

 

 

 

Character Delete

BS SP BS

 

 

 

 

Line Delete

Transmit total character number

 

 

of BS SP BS

 

 

 

 

Line Display

Display of last line of characters

 

 

 

*default

UTA220/UTA220k

12-31

Page 107
Image 107
Northern UTA220/UTA220k manual Parameter 19 Editing PAD Service Signals, PAD or parameter 6 is set to, D-Channel, Value