Setup menus

OPERATION menu

 

Item

 

Setting

 

V

V

 

 

 

 

Description of setting

T

T

 

Superimposed

 

Superimposed

No.

No.

R

R

 

display

display

 

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110

MEMORY STOP

 

 

This selects the processing to be conducted when the counter

 

 

 

 

 

 

displays zeros in the CTL mode or during FF or REW.

 

 

 

 

0000

OFF

0: The VTR is not shut down.

 

 

 

 

0001

ON

1: The VTR is automatically shut down.

 

 

 

 

 

 

<Note>

[

[

 

 

 

 

OFor the stop mode, either the stop or still-picture (SHTL + 0.0,

 

 

 

 

 

 

 

 

 

 

JOG STILL) mode is set depending on the setup menu item

 

 

 

 

 

 

No.315 (AFTER CUE-UP) setting.

 

 

 

 

 

 

OWhen both the AUTO REW function and MEMORY function

 

 

 

 

 

 

have been selected, the AUTO REW function takes priority.

 

 

 

 

 

 

 

 

 

170

HUMID OPE

 

 

This selects whether the unit is to continue operating when

 

 

 

 

 

 

condensation has formed.

 

 

 

 

0000

OFF

0: The unit does not operate.

 

 

 

 

0001

ON

1: It operates even when condensation has formed but no

 

[

 

 

 

 

guarantees are made for its operation.

 

 

 

 

 

 

 

 

 

 

 

<Note>

 

 

 

 

 

 

Since tape damage or other problems may occur when “1: ON”

 

 

 

 

 

 

has been selected, the “0: OFF” setting should normally be used.

 

 

 

 

 

 

 

 

 

171

ALL STOP SEL

 

 

This selects the unit’s mode to be established when the ALL

 

 

 

 

 

 

STOP button has been pressed.

 

 

 

 

0000

STOP

0: The unit is set to the STOP mode.

 

[

 

 

0001

STILL

1: The unit is set to the still-picture (SHTL + 0.0, JOG STILL)

 

 

 

 

 

 

mode.

 

 

 

 

 

 

 

 

 

172

VTR1 IN SEL

 

 

This selects the VIDEO/AUDIO input of VTR1 when the analog

 

 

 

 

 

 

signal input has been selected.

 

 

 

 

0000

V1 IN

0: VTR1 IN serves as the VTR1 input.

 

 

 

 

0001

V2 IN

1: VIDEO IN and AUDIO IN of VTR2 serve as the VTR1 input.

[

 

 

 

 

 

<Notes>

 

 

 

 

 

 

 

 

 

 

 

OThe unit will not operate when SDI signal input has been

 

 

 

 

 

 

selected.

 

 

 

 

 

 

OThis operation is not performed in the 625i mode.

 

 

 

 

 

 

 

 

 

173

BATTERY SEL

 

 

This selects the voltage threshold for warning when the DC supply

 

 

 

 

 

 

voltage has dropped.

 

 

 

 

 

 

(The unit’s power is automatically turned off when it drops to 10.6

 

 

 

 

 

 

V.)

 

 

 

 

0000

10.8V

0: When it has dropped to 10.8 V

 

 

 

 

0001

11.0V

1: When it has dropped to 11.0 V

 

 

 

 

0002

11.2V

2: When it has dropped to 11.2 V

 

[

 

 

0003

11.4V

3: When it has dropped to 11.4 V

 

 

 

 

0004

11.6V

4: When it has dropped to 11.6 V

 

 

 

 

0005

11.8V

5: When it has dropped to 11.8 V

 

 

 

 

0006

12.0V

6: When it has dropped to 12.0 V

 

 

 

 

0007

12.5V

7: When it has dropped to 12.5 V

 

 

 

 

0008

13.0V

8: When it has dropped to 13.0 V

 

 

 

 

 

 

 

 

 

174

SDI OUT

 

 

This selects the SDI output.

 

 

 

 

0000

VTR1

0: The VTR1’s signals are output.

 

[

 

 

0001

VTR2

1: The VTR2’s signals are output.

 

 

 

 

 

 

 

 

 

The underlining indicates the factory setting.