Setup menus

EDIT menu

 

Item

 

Setting

 

V

V

 

 

 

 

Description of setting

T

T

 

Superimposed

 

Superimposed

No.

No.

R

R

 

display

display

 

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

303

STD/NON-STD

 

 

This selects the STD or NON-STD to match the composite input

 

 

 

 

 

 

signals.

 

 

 

 

0000

AUTO

0: The standard/non-standard signals are automatically identified

 

 

 

 

 

 

and processed.

[

[

 

 

0001

STD

1: The standard signals are processed. (Forced STD)

 

 

 

 

 

 

0002

N-STD

2: The non-standard signals are processed. (Forced NON-STD)

 

 

 

 

 

 

<Note>

 

 

 

 

 

 

This operation is not performed in the 625i mode.

 

 

 

 

 

 

 

 

 

304

SERVO REF

 

 

This selects the servo synchronizing signals.

 

 

 

 

0000

AUTO

0: During recording or editing, the servo is synchronized with the

 

 

 

 

 

 

input signals; during playback, it is synchronized with the REF

[

[

 

 

 

 

signal.

 

 

 

 

0001

EXT

1: The servo is synchronized with the REF signal at all times.

 

 

 

 

 

 

 

 

 

305

EDIT RPLCE1

 

 

This selects the allocation of the channels using the controller’s

 

 

 

 

 

 

analog audio editing commands when a controller without

 

 

 

 

 

 

functions for digital audio editing is used to edit the digital audio

 

 

 

 

 

 

signals of the VTR.

 

 

 

 

 

 

The VTR’s channel 1 editing commands can be set ON or OFF in

 

 

 

 

 

 

accordance with the analog audio signals specified by the

 

 

 

 

 

 

controller.

 

[

 

 

0000

N-DEF

0: No setting

 

 

 

 

 

 

 

0001

CH1

1: Setting accords with the analog channel 1 editing commands.

 

 

 

 

0002

CH2

2: Setting accords with the analog channel 2 editing commands.

 

 

 

 

0003

CH1+2

3: Setting accords with the analog channel 1 or channel 2 editing

 

 

 

 

 

 

commands.

 

 

 

 

 

 

<Note>

 

 

 

 

 

 

This operation is not performed in the 625i mode.

 

 

 

 

 

 

 

 

 

306

EDIT RPLCE2

 

 

As with setup menu item No.305, this selects the VTR’s channel 2

 

 

 

 

 

 

editing commands ON or OFF in accordance with the analog

 

 

 

 

 

 

audio signals specified by the controller.

 

 

 

 

0000

N-DEF

0: No setting

 

 

 

 

0001

CH1

1: Setting accords with the analog channel 1 editing commands.

 

[

 

 

0002

CH2

2: Setting accords with the analog channel 2 editing commands.

 

 

 

 

 

 

 

0003

CH1+2

3: Setting accords with the analog channel 1 or channel 2 editing

 

 

 

 

 

 

commands.

 

 

 

 

 

 

<Note>

 

 

 

 

 

 

This operation is not performed in the 625i mode.

 

 

 

 

 

 

 

 

 

307

EDIT RPLCE3

 

 

As with setup menu item No.305, this selects the VTR’s channel 3

 

 

 

 

 

 

editing commands ON or OFF in accordance with the analog

 

 

 

 

 

 

audio signals specified by the controller.

 

 

 

 

0000

N-DEF

0: No setting

 

 

 

 

0001

CH1

1: Setting accords with the analog channel 1 editing commands.

 

[

 

 

0002

CH2

2: Setting accords with the analog channel 2 editing commands.

 

 

 

 

 

 

 

0003

CH1+2

3: Setting accords with the analog channel 1 or channel 2 editing

 

 

 

 

 

 

commands.

 

 

 

 

 

 

<Note>

 

 

 

 

 

 

This operation is not performed in the 625i mode.

 

 

 

 

 

 

 

 

 

308

EDIT RPLCE4

 

 

As with setup menu item No.305, this selects the VTR’s channel 4

 

 

 

 

 

 

editing commands ON or OFF in accordance with the analog

 

 

 

 

 

 

audio signals specified by the controller.

 

 

 

 

0000

N-DEF

0: No setting

 

 

 

 

0001

CH1

1: Setting accords with the analog channel 1 editing commands.

 

[

 

 

0002

CH2

2: Setting accords with the analog channel 2 editing commands.

 

 

 

 

 

 

 

0003

CH1+2

3: Setting accords with the analog channel 1 or channel 2 editing

 

 

 

 

 

 

commands.

 

 

 

 

 

 

<Note>

 

 

 

 

 

 

This operation is not performed in the 625i mode.

 

 

 

 

 

 

 

 

 

The underlining indicates the factory setting.

36