5. System settings

5-8. Status displays

5-8-1. Alarm status displays

The alert status (alarms) for this unit’s power supply and cooling fan are displayed on the LCD.

Press the [SYSTEM] button to light it, and display the SYSTEM menu.

Refer to “2-1-5. LCD menu area”.

Turn [F1] to display the Alarm sub menu.

<Menu display>

SYS

5Power Fan

Alarm

NoAlarmNoAlarm

Alarm Alarm

The alert status of the power supplies (mainframe and control panel) is displayed in the Power item. The alert status of the cooling fan (mainframe) is displayed in the Fan item.

NoAlarm: No irregularity

Alarm: Irregularity

5-8-2. Alarm message

A message is displayed on the LCD when an alarm has occurred.

Alarm message displayed

Type of trouble

Operation

ALARM ! FAN STOP

Cooling fan stopped (mainframe)

 

ALARM ! MF POWER FAILURE

Power supply voltage drop (mainframe)

 

ALARM ! MF POWER FAILURE &

Power supply voltage drop and cooling fan

 

FAN STOP

stopped (mainframe)

 

ALARM ! PANEL POWER FAILURE

Power supply voltage drop (control panel)

The alarm message disappears

ALARM ! PANEL POWER FAILURE &

Power supply voltage drop (control panel) and

when a menu operation is

FAN STOP

cooling fan stopped (mainframe)

performed.

ALARM ! PANEL & MF POWER

Power supply voltage drop (control panel and

 

FAILURE

mainframe)

 

ALARM ! PANEL & MF POWER

Power supply voltage drop (control panel

 

FAILURE & FAN STOP

and mainframe) and cooling fan stopped

 

 

(mainframe)

 

ALARM ! VER IS DISAGREEMENT

Mainframe and control panel versions do not

Recovery is not possible without

PANEL-Ver[] MF-Ver[xxxxxxx]

match

matching the versions of the

 

 

mainframe and control panel.

 

 

No operations can be performed

 

 

from the control panel until versions

 

 

are matched up.

ALARM ! LAN CONNECTION

LAN communication malfunction between

The message remains displayed

ERROR

mainframe and control panel

and no operations can be performed

 

 

from the control panel until the

 

 

trouble is remedied and normal

 

 

operation is restored.