141
5. System settings
5-7-2. Editor control
The following lists the functions which can be controlled by editing controller AG-A850.
(Compliant with the GVG protocol)
• Read command
• Crosspoint switch
• Wipe pattern selection (BKGD)
• Transition mode (MIX/WIPE) selection
• Auto transition time setting
• Auto transition execution
<Table of wipe patterns supported>
GVG
protocol AV-HS450N GVG
protocol AV-HS450N GVG
protocol AV-HS450N GVG
protocol AV-HS450N
1 WIPE #1 22 SQ1 #10 43 3D1 #7 64 SL2 #4
2 WIPE #2 23 44 3D1 #8 65
3 WIPE #3 24 SQ1 #12 45 3D1 #9 66 SL2 #6
4 WIPE #4 25 SL1 #1 46 3D1 #10 67
5 WIPE #5 26 SL1 #2 47 3D1 #11 68 SL2 #8
6 WIPE #6 27 SL1 #3 48 3D1 #12 69
7 WIPE #7 28 SL1 #4 49 70
8 WIPE #8 29 SL1 #5 50 SQ2 #2 71
9 WIPE #9 30 SL1 #6 51 72
10 WIPE #10 31 SL1 #7 52 SQ2 #4 73
11 WIPE #11 32 SL1 #8 53 74 SD2 #2
12 WIPE #12 33 SL1 #9 54 SQ2 #6 75
13 SQ1 #1 34 55 76 SD2 #4
14 SQ1 #2 35 56 SQ2 #8 77
15 SQ1 #3 36 57 78 SD2 #6
16 SQ1 #4 37 3D1 #1 58 79
17 SQ1 #5 38 3D1 #2 59 80 SD2 #8
18 SQ1 #6 39 3D1 #3 60 81
19 SQ1 #7 40 3D1 #4 61 82
20 SQ1 #8 41 3D1 #5 62 SL2 #2 83
21 SQ1 #9 42 3D1 #6 63 84
On the RS422 sub menu of the CTL menu, set On or Off for control from the external device (editor) connected to
the RS-422 connector.
For details on the settings, see “5-7-1. Enable/Disable Setting for Control of External Devices”.