75
3. Basic operations
3-6-5. DSK adjustments
The DSK definition can be adjusted.

Press the [DSK1] button (or [DSK2] button) to light its indicator and display the DSK1 menu (or DSK2
menu).
Refer to “2-1-5. LCD menu area”.

Turn [F1] to display the Adjust sub menu.
<Menu display>
DSK1 2|Clip |Gain |Density|Invert
Adjust | 0.0| 100.0| 100.0| Off

Turn [F2], [F3] and [F4] to adjust the DSK (downstream key) definition.

Turn [F5] to set key invert.
If On is set, the key signals generated internally are inverted.
Operation Parameter Description of setting Setting range
F2 Clip Reference level for generating key signals 0.0 to 108.0
F3 Gain Key amplitude 0.0 to 200.0
F4 Density Key density 0.0 to 100.0
F5 Invert Key signal inversion On, Off