3. Basic operations

Step 5

The objective of this step is to finely adjust the image by adjusting the noise and transparency, for example.

On the CHR KEY menu, turn [F1] to display the Sample2 sub menu.

<Menu display>

CHRKEY 3View Mode

UNDO↓

Sample2 Cmpsit Spill-

 

 

 

 

 

 

Matte

Spill+

 

 

 

Proc.FG

Matte-

 

 

 

FG

Matte+

 

 

 

 

Detail-

 

 

 

 

 

 

 

Detail+

 

 

 

 

MatSpng

 

 

 

 

MkFGTrn

 

 

 

 

RstrDtl

 

 

 

 

 

 

 

Turn [F2] to select the image to be adjusted using the View item.

Cmpsit: Composite image that combines the background image and key

Matte: Matte image

Proc.FG: Process foreground image

FG: Foreground image

Turn [F3] to select the adjustment function using the Mode item. For details on the items, refer to the following pages.

Using the positioner, move the position of the sample marker to the position to be sampled. To change the size of the sample marker, turn the rotary encoder [Z].

If the sample area that has been set is acceptable, press the rotary encoder [Z]. The area that has been set is now sampled.

To return to the pre-sampling status after sampling has been executed, press [F5]. The number of operations that can be undone is one only.

57

Page 57
Image 57
Panasonic AV-HS450N manual Chrkey 3 View Mode