86
3. Basic operations
3-10-3. Recalling the operations stored in the memory (Recall)
123
456
789
10 XPT DSBL EFF DSLV
WIPE
SQ1 SQ2
SL2SL1
3D1 3D2
PAGE
STOR
DEL
UNDO
BKGD
WIPE
MEM
RE
CALL
SHOT
MEM
PinP
MEM
CAM
MEM
BKGD
PATT
KEY
PATT
12
4
3
56
789
10 12
MEMORY / PATTERN
11
Recall

Press one of the buttons — [SHOT MEM], [BKGD WIPE MEM], [PinP MEM] or [CAM MEM] — to select the
corresponding memory whose operations are to be recalled.
The selected button lights in amber.
Depending on the operation that was performed last, the [STOR] button, [RECALL] button or [DEL] button
lights.

Press the [RECALL] button. The [RECALL] button lights in amber.
The button of the number key containing the stored operations lights in green (or in amber with the AW
system).
However, it will not light if [CAM MEM] has been selected.

Press the number key (1 to 10) whose stored operations are to be recalled.
The items of the selected memory unit are targeted as the stored operations that will be recalled.
Refer to “3-10-1. Memory registration and recall items”.
When another number button is pressed, the memory items stored in the pressed button will be recalled.

As soon as the stored operation that has been recalled is played, the [UNDO] button becomes operable, and
it lights in amber.
If the [UNDO] button is pressed while it is lighted, the status before the stored operation is played will be
restored.
When the [CAM MEM] button is selected, the [UNDO] button will have no effect so it will not light.
The [CAM MEM] button uses the preset numbers stored in the pan-tilt heads.
Bear in mind that if the preset details have been changed at the pan-tilt head after a preset number was
stored using the [CAM MEM] button, it will be the changed details that will be recalled.

To exit memory recall, press the [STOR] button or [SHOT MEM] button.
XPT DSBL
When number key No.11 [XPR DSBL] is pressed while a stored operation is playing, it will light in amber. When
the [RECALL] button is now pressed, the selected materials of the PGM/A bus, PST/B bus, KEY bus, PinP1/2 bus
and DSK1/2 bus will be excluded from the target for stored operations.
The number key No. 11 [XPT DSBL] will not light when the [CAM MEM] button is selected, as the operations of
the key are disabled.