4. Input/output signal settings
4-1-7. Setting the analog composite input signals (option)
When the analog composite input board (option) has been connected, the analog composite input signals can be
set.

Press the [INPUT] button to light its indicator and display the INPUT menu.
Refer to “2-1-5. LCD menu area”.

Turn [F1] to display the INPUT XX sub menu.
(X: A1, A2, B1 or B2)
The input used to set the analog composite signal is selected for X.

Turn [F2] to display the third menu of Setting.
<Menu display>
INPUT XX|Setting|Chroma |Ped |Hue
| 3/5 | 0| 0| 0
−8~+7 −100
|
+100
−30~+30

Turn [F3] to adjust the chroma level using the Chroma item.
(Maximum amount of variation: approx. ±3 dB)
The Auto Color Control function is activated, and the chroma level is kept at the value that has been set.

Turn [F4] to adjust the pedestal level using the Ped item.
(Maximum amount of variation: approx. ±100 mV)

Turn [F5] to adjust the hue using the Hue item.
(Maximum amount of variation: approx. ±20°)
Adjustment of Hue is possible when the system format is 1080/59.94i, 720/59.94p and 480/59.94i.
For details on the other settings, refer to the operating instructions of the optional board.