179
Menu Sub menu Parameter 1 Parameter 2 Parameter 3 Parameter 4
Turn F1 to select. Turn F2 to select. Turn F3 to select. Turn F4 to select. Turn F5 to select.
SYSTEM
(When
locked)
(Message) Parameter The SYSTEM menu is locked.
Display only
SYSTEM
(When
unlocked)
SYS 1 Parameter Mode HiRes 16:9SQ
Format Setting range 1080/59.94i, 1080/50i, 1080/24psf,
1080/23.98psf, 720/59.94p, 720/50p,
480/59.94i, 576/50i
On, Off
(Selection enabled
when SD format is
used)
On, Off
(Selection enabled
when SD format is
used)
Default value 1080/59.94i Off Off
SYS 2 Parameter System H-Phase V-Phase
OutPhs Setting range 0H, 1H –1320 to +1319 –100 to +100
Default value 1H 0 0
SYS 3 Parameter Sync BBSetup GenLock
Ref Setting range BBST, BBAD,
TRI, INT
0IRE, 7.5IRE Locked, UnLock
Default value BBST 7.5IRE
SYS 4 Parameter VAnci E.Audio
Anci Setting range On, Off On, Off
Default value Off Off
SYS 5 Parameter Power Fan
Alarm Setting range Alarm, NoAlarm Alarm, NoAlarm
Default value Alarm Alarm
SYS 6 Parameter Init F Init
Initial Setting range
Default value
SYS 7 Parameter IP Address Save
NetWork1 Setting range 0 to 255 0 to 255 0 to 255 0 to 255
Default value 192 168 0 10
SYS 8 Parameter Subnet Mask Save
NetWork2 Setting range 0 to 255 0 to 255 0 to 255 0 to 255
Default value 255 255 255 0
SYS 9 Parameter MAC Address
NetWork3 Display only
SYS 10 Parameter Year Month Date Set
Date Setting range 2000 to 2099 1 to 12 1 to 31
Default value
SYS 11 Parameter Hour Minute Second Set
Time Setting range 0 to 23 0 to 59 0 to 59
Default value