1. Installation

1-1. Installing the control panel

Follow the instructions set forth in “Safety precautions” and also observe the cautionary items below.

Be absolutely sure to ask your dealer to do the jobs of installing and connecting the panel.

Connecting the power supply

Be absolutely sure to use only the power cord and AC adapter supplied with the panel.

Be absolutely sure to connect the grounding terminal of the power cord to ground.

Also connect the ground terminal (SIGNAL GND) at the rear of the panel to the system ground.

If only one AC adapter is to be connected, place the dust-proof cap over the DC power input socket that is not going to be used.

To prevent the DC plug from being disconnected, secure the cable of the AC adapter to the cable clamp.

When the control panel is not going to be used for a prolonged period of time, set its power switch to the “off” position to conserve power, and disconnect the power plug.

Dust-proof cap

POWER

OFF

 

IN2

ON

LCD CONTRAST

IN1 12V

 

12V

 

MAINFRAME

Cable clamp

Handle the control panel carefully!

Dropping the control panel or subjecting it to strong impact or vibration may cause trouble and/or malfunctioning.

Do not allow any foreign objects to enter inside the control panel!

Allowing water, metal items, scraps of food or other foreign objects inside the control panel may cause a fire and/or electric shocks.

Choosing the best installation location

This unit is designed for indoor use only.

Install the unit on a sufficiently strong, stable and level surface for use.

Ensure a space of at least 100 mm around the rear vents to avoid obstructing ventilation.

In particular, ensure sufficient space between ventilation and wiring when using mounted in a panel or table.

Do not install the panel in a cold place where the temperatures will drop below 32 °F (0 °C) or in a hot place where the temperatures will rise above 104 °F (40 °C).

Avoid installing the panel where it will be exposed to direct sunlight or to the hot air that is blown out from other products.

Installing the panel in a very humid, dusty or vibration- prone location may give rise to trouble.

Ventilation holes

Multi-format Live Switcher AV-HS450

12

Page 12
Image 12
Panasonic AV-HS450N manual Installation, Installing the control panel, Handle the control panel carefully