164
Menu Sub menu Parameter 1 Parameter 2 Parameter 3 Parameter 4
Turn F1 to select. Turn F2 to select. Turn F3 to select. Turn F4 to select. Turn F5 to select.
CHR KEY CHRKEY 1 Parameter AutCmp RESET
AutoCmp Setting range
Default value
CHRKEY 2 Parameter View Mode UNDO
Sample1 Setting range Cmpsit, Matte,
Proc.FG, FG
SelBG, Cln.BG,
Cln.FG, Spl.Spg
Default value Cmpsit SelBG
CHRKEY 3 Parameter View Mode UNDO
Sample2 Setting range Cmpsit, Matte,
Proc.FG, FG
Spill–, Spill+,
Matte–, Matte+,
Detail–, Detail+,
MatSpng,
MkFGTrn, RstrDtl
Default value Cmpsit Spill–
CHRKEY 4 Parameter View Spill Trans Detail
FineTun Setting range Cmpsit, Matte,
Proc.FG, FG
–1000 to 1000 –1000 to 1000 –1000 to 1000
Default value Cmpsit 0 0 0
PinP1 PinP1 1 Parameter Shape CrclAsp Density PVW
PinP1 Setting range Square, Circle 0.0 to 100.0 0.0 to 100.0 On, Off
Default value Square 0.0 100.0 Off
PinP1 2 Parameter Border Width Soft Mode
Border Setting range Off, On 0.1 to 100.0 0.0 to 100.0 Fix, Var
Default value Off 5.0 0.0 Fix
PinP1 3 Parameter Hue Sat Lum Load
BodrCol Setting range 0.0 to 359.9 0.0 to 100.0 0.0 to 108.0 White, Yellow,
Cyan, Green,
Magenta, Red,
Blue, Black
Default value 0.0 0.0 100.0 White
PinP1 4 Parameter X-Pos Y-Pos Size
Position Setting range −50.00 to 50.00 −50.00 to 50.00 0.00 to 100.00
Default value 0.00 0.00 25.00
PinP1 5 Parameter XYZ
Rotation Setting range –360 to 360 –360 to 360 –360 to 360
Default value 0 0 0
8. Setting menu table