3.10 Connection of 2.4 GHz Portable Stations
3.10.7 Connecting a Cell Station to the PBX
Using a CSIF Card
Refer to the following example to connect a CS to the PBX.
KX-TDA0152/KX-TDA0142
CSIF8 Card
Port 1
Cable | Maximum Distance |
ø 0.4 mm: | 444 m |
ø 0.5 mm: | 694 m |
ø 0.6 mm: | 1000 m |
CAT 5: | 694 m |
|
|
|
| CSIF card (RJ45) | |
|
|
|
|
|
|
CS (RJ11) |
|
| Pin No. | Signal Name | |
|
| 1 |
| ||
|
|
|
|
| |
Signal Name |
| Pin No. |
| 2 |
|
D1 |
| 1 |
| 3 | D1 |
|
| ||||
POWH |
| 2 |
| 4 | POWH |
|
| ||||
POWL |
| 3 |
| 5 | POWL |
|
| ||||
D2 |
| 4 |
| 6 | D2 |
|
| ||||
|
|
|
| 7 |
|
|
|
|
| 8 |
|
Accessories and User-supplied Items for the CS
Accessories (included): Screws × 2, Washers × 2
User-supplied (not included): RJ11 connector
Note
For details about CSIF card, refer to "3.6.1 CSIF4 Card