1.4 Specifications

1.4.2Characteristics

Terminal Equipment Loop Limit

• PT: KX-T7600 series DPT: 90 ; all other DPTs/APTs: 40

 

• SLT: 600 including set

 

• Doorphone: 20

 

• CS: 130 ; PT-interface CS (Basic/High-density): 65

 

 

Minimum Leakage Resistance

15 000 minimum

 

 

Maximum Number of Extension

1 for PT or SLT

Instruments per Line

2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT

 

 

3 by Digital eXtra Device Port connection of 2 DPTs and an SLT

 

 

Ring Voltage

75 Vrms at 20 Hz/25 Hz depending on the Ringing Load

 

 

Trunk Loop Limit

1600 maximum

 

 

Hookswitch Flash/Recall Timing

24 ms to 2032 ms

Range

 

 

 

BRI Cards Internal ISDN Mode

Supply Voltage: 40 V

 

Power Supply (BRI4): 4.5 W per 1 line, 10 W per 4 lines

 

Power Supply (BRI8): 4.5 W per 1 line, 20 W per 8 lines

 

Power Supply Method: Phantom Power Supply

 

 

Door Opener Current Limit

24 V DC/30 V AC, 1 A maximum

 

 

External Relay Current Limit

24 V DC/30 V AC, 1 A maximum

 

 

External Sensor Current Limit

Power to the external sensor is provided from the EIO4 card and must be

 

grounded through the EIO4 card. For the connection diagram, refer to

 

"3.7.4 EIO4 Card (KX-TDA0164)".The PBX detects input from the sensor

 

when the signal is under 100 .

 

 

Paging Terminal Impedance

600

 

 

MOH (Music on Hold) Terminal

10 000

Impedance

 

 

 

32

Installation Manual

Page 32
Image 32
Panasonic KX-TDE100 installation manual Characteristics