| 5.1 Troubleshooting |
|
|
|
|
|
|
|
|
|
| Item | Description |
|
|
|
|
5 | Sub Code | The |
•X: Shelf type
–Physical shelf: " " (blank)
–Virtual shelf: "*" (asterisk)
•1: Shelf number
•YY: Slot number
–
(00: IPCMPR Card Slot; 01 to 06: Free Slots)
–
(00: IPCMPR Card Slot; 01 to 11: Free Slots)
–
(01 to 04: Virtual Trunk Slots; 05 to 08: Virtual Extension Slots)
•ZZ: Port number
–For optional service cards except OPB3 card: Port number (01 to 16) will be displayed.
–For OPB3 card:
Sub slot number (1 to 3) + port number (1 to 4) will be displayed as follows:
•Sub slot 1 of OPB3: 11 to 14
•Sub slot 2 of OPB3: 21 to 24
•Sub slot 3 of OPB3: 31 to 34
|
| Note |
|
| When there is no parameter for slot and port number, YY |
|
| and ZZ will be displayed as "00". |
|
| Example: Sub code for IPCMPR card = " 10000" |
|
|
|
6 | Error Message | A description of the error. |
|
|
|
7 | Log Information | Displays probable causes of the errors and their solutions. |