Panasonic AJ-HD1700PE Return format VTR controller PC, Error code table, Send command, data

Models: AJ-HD1700PE

1 134
Download 134 pages 5.53 Kb
Page 124
Image 124
3. Return format

RS-232C interface

3. Return format

[VTR > controller (PC)]

The following responses are made to the commands. If necessary, more than one response is made.

When the communication has ended successfully

1. The receive completion message is returned.

[ACK]

06h

2.The execution completion message is returned.

4. Error code table

ER001: Invalid command

Unsupported command received

Command execution error

ER002: Parameter error

ER102: VTR mode error (front loading motor)

ER103: VTR mode error (loading motor)

ER104: VTR mode error (drum, capstan system)

ER105: VTR mode error (reel system)

ER106: VTR mode error (tension system)

ER108: VTR condensation error

ER1FF: VTR system error

[STX]

[command]

[data]

 

[ETX]

02h

XX XX XX

XX

.....

XX

03h

 

[command]:

This is the message (data) which is returned or the execution completion message identifier.

[data]:

This is the data to be returned. It can be omitted.

Example:

Send command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Return message (data)

[STX] OPL [ETX] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 [ACK] [STX] OPL [ETX]

When the communication has ended unsuccessfully

[NACK]

15h

When processing is not possible due to incorrect data or problem with the VTR

1.The receive completion message is returned.

[ACK]

06h

2. An error code is returned.

[STX]

[E R N1 N 2 N 3 ]

[ETX]

02h

Error code

03h

124

Page 124
Image 124
Panasonic AJ-HD1700PE Return format VTR controller PC, Error code table, ∫ When the communication has ended successfully