Panasonic AJ-HD1700PE Software specifications protocol, Send format, controller PC, ∫ Data format

Models: AJ-HD1700PE

1 134
Download 134 pages 5.53 Kb
Page 123
Image 123
Software specifications (protocol)

RS-232C interface

Software specifications (protocol)

1.Communication parameters

Communication

 

Asynchronous, full duplex

 

system

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transfer rate

 

300, 600, 1200, 2400, 4800 or 9600

 

bps

 

 

 

 

 

 

 

Bit length

 

7 bits or 8 bits

 

 

 

 

 

 

 

 

 

 

Stop bit

 

1 bit

or 2 bits

 

 

 

 

 

 

 

 

Parity bit

 

None

 

, odd or even

 

 

 

 

 

 

 

ACK code

 

Returned

 

or not returned

 

 

 

<Note>

 

 

 

 

 

 

 

ACK is the code which is returned from the

 

 

 

VTR to the controller when data has been

 

 

 

successfully sent from the controller.

 

 

 

 

 

 

 

 

 

 

 

The underlining (__) denotes the factory setting mode.

Any changes to the settings can be made using the setup menu items listed below.

Communication

Setup menu item

parameter

 

 

 

 

 

Transfer rate

No.205 BAUD RATE

 

 

Bit length

No.206 DATA LENGTH

 

 

Stop bit

No.207 STOP BIT

 

 

Parity bit

No.208 PARITY

 

 

ACK code

No.209 RETURN ACK

 

 

2. Send format

> VTR]

[controller (PC)

Data format

[STX]

[command]

[:]

[data]

[ETX]

02h

XX XX XX

3Ah XX

.....

XX

03h

 

20H<XX<7FH

(XX=ASCII code: symbols, numbers, upper- case letters)

[command]:

This is the command identifier (3 bytes).

A3-byte identifier (ASCII code: symbols, numbers, upper-case letters) is sent as the command.

[:]

The colon is the code serving as a delimiter between the command and data.

[data]:

Data (ASCII code: symbols, numbers, upper- case letters) can be added in the number of bytes required.

Outline of procedure for sending data from controller

1The send command starts with STX (start of text = 02h). The command is then identified by COMMAND which follows, and the data is added as required.

The command ends with ETX (end of text =

03h).

2When a different command is to be sent, a response is awaited from the VTR, and then

the command is sent. (See page 124.)

3If STX is sent again before ETX is sent, the receive data buffer inside the VTR is cleared. A command error is returned to the controller, and the data is newly processed with STX which was received again at the head.

123

Page 123
Image 123
Panasonic AJ-HD1700PE Software specifications protocol, Send format, controller PC, Communication parameters, command