Function menus

50P IN/OUT ASSIGN

<50P IN/OUT ASSIGN>

50-pin assignment factory settings

Pin

I/O

Setting item

no.

 

 

 

 

 

 

 

 

 

1

I

REC

 

 

 

2

I

PLAY

 

 

 

3

I

FF

 

 

 

4

I

REW

 

 

 

5

I

STOP

 

 

 

6

I

___

 

 

 

7

I

___

 

 

 

8

I

422 REMOTE ON

 

 

 

9

I

422 REMOTE OFF

 

 

 

10

I

LOCAL ENABLE

 

 

 

11

I

EJECT

 

 

 

12

I

IN SET

 

 

 

13

I

REC INH ALL

 

 

 

14

I

REC INH PRE

 

 

 

15

I

LOCAL DISABLE

 

 

 

16

I

TC EXT

 

 

 

17

I

TC INT&TCG MODE AUTO

 

 

 

18

I

___

 

 

 

19

I

___

 

 

 

20

I

STNDBY ON/OFF

 

 

 

21

O

ERR0 STATUS

 

 

 

22

I

DET STOP ON

 

 

 

23

I

CUE

 

 

 

24

O

ERR1 STATUS

 

 

 

25

I

DET STOP OFF

 

 

 

26

Power

 

 

 

 

27

O

REC STATUS

 

 

 

28

O

PLAY STATUS

 

 

 

29

O

FF STATUS

 

 

 

30

O

REW STATUS

 

 

 

31

O

STOP STATUS

 

 

 

32

O

422 REMOTE STATUS

 

 

 

33

O

EJECT STATUS

 

 

 

34

O

ERR2 STATUS

 

 

 

35

O

TC SRC1 STATUS

 

 

 

36

O

TC SRC2 STATUS

 

 

 

37

O

___

 

 

 

38

O

___

 

 

 

39

O

REC INH1 STATUS

 

 

 

40

O

REC INH2 STATUS

 

 

 

Pin

I/O

Setting item

no.

 

 

 

 

 

 

 

 

 

41

O

CUE STATUS

 

 

 

42

O

REMOTE STATUS

 

 

 

43

O

DET STOP STATUS

 

 

 

44

O

PRE CTL DETECTED STATUS

 

 

 

45

O

LOCAL ENABLE STATUS

 

 

 

46

O

STANDBY ON STATUS

 

 

 

47

GND

 

 

 

 

48

O

___

 

 

 

49

GND

 

 

 

 

50

GND

 

 

 

 

__

“ ” denotes that nothing is subject to control or to a status.

<Notes>

For a command, input TTL level signals; for an active low edge, input an electrical signal of 100 ms

or more.

For a status, a maximum open collector and sink current of 6 mA is output.