Panasonic AJ-HD1700PE operating instructions Time Code, Setup menus, Regen

Models: AJ-HD1700PE

1 134
Download 134 pages 5.53 Kb
Page 91
Image 91
<TIME CODE>

Setup menus

<TIME CODE>

No./Item

 

 

 

Description of setting

 

 

 

 

 

 

 

 

 

 

500* 4

For selecting whether or not to output the

 

VITC signal at the positions selected by setup

VITC BLANK

menu items No.501 (VITC POS-1) and No.502

 

(VITC POS-2).

 

 

0000

BLANK

: The VITC signal is not output.

 

 

0001

THRU

: The VITC signal is output.

 

 

 

 

 

 

<Note>

Only the SD output takes effect at this setting.

501*4

For setting the position where the VITC signal

 

is to be inserted.

 

 

 

 

VITC POS-1

<59/60Hz>

 

<50Hz, 25Hz (SD)>

 

0000

 

10L

0000

 

 

7L

 

:

:

:

:

 

0006

 

16L

0004

 

11L

 

 

 

 

 

 

 

 

 

 

 

:

:

:

:

 

0010

 

20L

0015

 

22L

<Notes>

The same line as the one selected by the setup menu item No.502 (VITC POS-2) cannot be selected.

Only the SD output takes effect at this setting.

502*4

For setting the position where the VITC signal

 

is to be inserted.

 

 

 

 

VITC POS-2

<59/60Hz>

 

 

 

<50Hz, 25Hz (SD)>

 

0000

 

10L

0000

 

 

7L

 

:

:

:

:

 

0008

 

 

18L

0006

 

13L

 

 

 

 

 

 

 

 

 

 

 

 

 

:

:

:

:

 

0010

 

20L

0015

 

22L

<Notes>

The same line as the one selected by the setup menu item No.501 (VITC POS-1) cannot be selected.

Only the SD output takes effect at this setting.

503*1

For setting the synchronization of the internal

 

time code generator.

 

 

 

 

TCG MODE

0000

REGEN

:

 

 

 

 

 

 

The time code reader is synchronized with the

 

 

time code which is read from the tape.

 

 

 

0001

 

PRE

:

 

 

 

 

 

 

Presetting is enabled at the operation panel or

 

 

by the remote controller.

 

 

 

 

 

0002

 

AUTO

:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The

REGEN

 

and

PRE

settings

are

 

 

automatically switched in accordance with the

 

 

operation mode.

 

 

 

 

 

 

 

 

In the editing mode: REGEN is selected.

 

 

 

In all other modes: PRE is selected.

 

 

 

 

 

 

 

 

 

504*1

For setting

when the

internal

 

time

code

 

generator is to advance depending on the

 

RUN MODE

operation mode.

 

 

 

 

 

 

 

0000

 

REC

:

 

 

 

 

 

 

 

 

 

 

 

 

 

The time code generator is advanced during

 

 

 

recording.

 

 

 

 

 

 

 

 

 

0001

FREE

:

 

 

 

 

 

 

The time code generator is advanced while the

 

 

 

power is

on

regardless

of which

operation

 

 

mode is established.

 

 

 

 

*1: This item is not displayed when the 23/24 Hz or 25 Hz (HD or SD) mode has been selected as the system menu item No.25 (SYSTEM FREQ) setting.

*2: This item is not displayed when the 23/24 Hz or 25 Hz (HD) mode has been selected as the system menu item No.25 (SYSTEM FREQ) setting.

The underlining (__) denotes the factory setting mode.

No./Item

 

 

 

 

Description of setting

 

 

 

 

 

 

 

 

 

505*1

For selecting the

regeneration

signal when

 

REGEN has been selected as the TCG (time

TCG REGEN

code generator) mode.

 

 

 

 

 

0000

 

TC&UB

 

:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Regeneration applies to both the time

code

 

 

and user’s bit.

 

 

 

 

 

 

 

0001

 

TC

 

:

 

 

 

 

 

 

Regeneration applies only to the time code only.

 

0002

 

UB

 

:

 

 

 

 

 

 

Regeneration applies only to the user’s bit only.

 

 

 

 

 

 

 

 

 

 

506*1

For selecting the

editing

mode

range when

 

the VTR is operating in the REGEN mode

REGEN MODE

while

performing editing

operations

with

 

“AUTO” selected as the setup menu item

 

No.503 (TCG MODE) setting.

 

 

 

 

0000

 

AS&IN

 

:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Regeneration

applies

during

assemble

or

 

 

insert editing.

 

 

 

 

 

 

 

0001

ASSEM

 

:

 

 

 

 

 

 

Regeneration applies during assemble editing.

 

0002

INSRT

 

:

 

 

 

 

 

 

Regeneration applies during insert editing.

 

 

 

 

 

 

 

 

507*1

For selecting the time code to be used when

 

HD SDI

or SD SDI has been selected as the

TC SOURCE

setup

menu item No.600 (VIDEO IN SEL)

 

setting when an external time code is to be

 

used.

 

 

 

 

 

 

 

 

 

 

[When HD SDI has been selected]

 

 

 

0000

 

INT

:

 

 

 

 

 

 

 

 

 

 

 

 

The

time code of the internal time code

 

 

generator is used.

 

 

 

 

 

 

0001

EXT_L

 

:

 

 

 

 

 

 

LTC of the TIME CODE IN connector is used.

 

0002

 

SLTC

 

:

 

 

 

 

 

 

The

LTC information added to the

serial

 

 

signals which are input to HD SDI IN is used.

 

0003

SVITC

 

:

 

 

 

 

 

 

The VITC information added to the serial

 

 

signals which are input to HD SDI IN is used.

 

[When SD SDI has been selected]

 

 

 

0000

 

INT

:

 

 

 

 

 

 

 

 

 

 

 

 

The

time code of the internal time code

 

 

generator is used.

 

 

 

 

 

 

0001

EXT_L

 

:

 

 

 

 

 

 

LTC of the TIME CODE IN connector is used.

 

0002

 

VITC

 

:

 

 

 

 

 

 

The VITC information added to the serial

 

 

signals which are input to SD SDI IN is used.

 

<Note>

 

 

 

 

 

 

 

If the VIDEO IN SEL input selection is changed, the time

 

code is converted as shown below.

 

 

 

 

 

[HD_SDI]

 

[SD_SDI]

 

 

 

INT

 

 

INT

 

 

 

 

EXT_L

 

 

EXT_L

 

 

 

 

SLTC

 

 

EXT_L

 

 

 

 

SVITC

 

 

VITC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91

Page 91
Image 91
Panasonic AJ-HD1700PE operating instructions Time Code, Setup menus, Regen