3.2 Installation of the PBX
3.2.4Installing/Replacing the Power Supply Unit
Function
PSU Type | Lower/Upper Input Voltage Range | Current | Input Frequency | |
|
|
|
| |
Lower: 100 V AC to 130 V AC | 1.4 A |
| ||
(for |
|
|
| |
Upper: 200 V AC to 240 V AC | 0.8 A |
| ||
|
| |||
|
|
|
| |
Lower: 100 V AC to 130 V AC | 2.5 A |
| ||
(for |
|
| 50 Hz or 60 Hz | |
Upper: 200 V AC to 240 V AC | 1.4 A | |||
TDE200) |
| |||
|
|
| ||
|
|
|
| |
| Lower: 100 V AC to 130 V AC | 5.1 A |
| |
(for |
|
|
| |
Upper: 200 V AC to 240 V AC | 2.55 A |
| ||
|
| |||
|
|
|
|
Battery Switch
Battery Connector
Power Switch
Earth Terminal
AC Inlet
Battery Switch
Battery Connector
Earth Terminal
Power Switch
AC Inlet
Accessories and User-supplied Items
Accessories (included): Screws × 4
Notes
•For details about frame earth connection, refer to "3.2.5 Frame Earth Connection".
•For details about backup batteries connection, refer to "3.2.6 Backup Battery Connection".
Safety Instructions
Each PSU complies with Safety Class 1 of IEC60950, EN60950, UL60950,
When installing or replacing a PSU, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:
1.Never install or replace a PSU during a lightning storm.
2.Never install or replace a PSU in wet locations.
52