3.8 Connection of Extensions
3.8.3Digital EXtra Device Port (Digital XDP) Connection
A DPT can be connected to another DPT on the Digital XDP connection. In addition, if the DPT is connected to a DHLC8 card, it can also have an SLT connected in Parallel mode or XDP mode.
Notes
•Both DPTs must be
•Parallel mode or XDP mode can be selected through system programming.
•If XDP mode is enabled through system programming, parallel connection is not possible. Refer to "1.11.9 Paralleled Telephone" and "2.1.1 Extension Port Configuration" in the Feature Guide for further information.
With KX-T7600 Series DPT (except KX-T7600E Series)
Using a Modular T-Adaptor
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
Modular
Connect pins "T" and "R".
| SLT |
Master DPT | Slave DPT |
Back View of DPTs |
|
TO TEL | TO MAIN UNIT |
| |
| / PABX |
Cable | Maximum Distance |
ø 0.4 mm: | 30 m |
ø 0.5 mm: | 50 m |
ø 0.6 mm: | 60 m |
CAT 5: | 50 m |
TO MAIN UNIT |
|
|
/ PABX | Master DPT | Slave DPT |
| ||
| To DLC8/DLC16 card |
|
| To DHLC8 card |
|
| (for connection of SLT) |
|