Panasonic KX-TDE100 installation manual Trunk is connected to the T2/R1

Models: KX-TDE100

1 252
Download 252 pages 50.17 Kb
Page 240
Image 240

5.1 Troubleshooting

(Continued from the previous page.)

Can you dial

No

out on a

 

 

trunk?

 

Connection between the trunk and the PBX:

 

 

CAUSE

SOLUTION

Trunk is connected to the T2/T1.

Reconnect the trunk to

 

 

 

 

 

 

the T1/R1 or T2/R2 of the

 

 

 

 

 

 

telephone jack using 2-

 

 

 

 

T2

 

 

 

 

 

R1

 

conductor wiring.

 

 

 

 

T1

 

 

 

 

 

 

R2

 

 

 

 

 

 

 

 

 

 

Trunk

 

 

PBX

 

Trunk is connected to the T2/R1.

T2

R1

T1

R2

Trunk PBX

240 Installation Manual

Page 240
Image 240
Panasonic KX-TDE100 installation manual Trunk is connected to the T2/R1