Panasonic R410A Service procedures, HIC-CH4872R, HIC-CH2672R, 26, 36 Type, Alarm “E31”

Models: R410A

1 198
Download 198 pages 33.93 Kb
Page 174
Image 174
HIC-CH4872R

4. Service procedures

HIC-CH4872R

HIC-CH2672R

(42 Type)

(26, 36 Type)

 

 

 

Resistance

 

 

 

 

Between terminals

 

Resistance

 

 

 

 

 

HIC +

 

HIC –

 

200 kor more

 

 

 

 

 

 

HIC +

 

U

 

300 kor more

 

 

 

 

 

 

HIC +

 

V

 

300 kor more

 

 

 

 

 

 

HIC +

 

W

 

300 kor more

 

 

 

 

 

 

HIC –

 

U

 

200 kor more

 

 

 

 

 

 

HIC –

 

V

 

200 kor more

 

 

 

 

 

 

HIC –

 

W

 

200 kor more

 

4

(3) [Alarm “E31”]

IGBT short-circuit protection

(communications

 

 

 

trouble within unit)

 

 

 

 

Is “E31”

No

 

 

 

 

displayed even after

 

 

the power voltage

Normal

 

 

 

is reset?

Yes

Replace outdoor unit control PCB.

4-10

Page 174
Image 174
Panasonic R410A service manual Service procedures, HIC-CH4872R, HIC-CH2672R, 26, 36 Type, Alarm “E31”, communications