7-2. Room Temperature Sensor Setting

1. Specifications

7-2. Room Temperature Sensor Setting

The room temperature sensors are built into the indoor unit and the wireless remote controller. Either of these room temperature sensors can operate.

The system is shipped from the factory set to the indoor unit sensor. To switch to the remote control sensor, press the sensor switching button located inside the remote control cover and check that A/C SENSOR on the LCD display panel goes out.

NOTE

If the sensor switch is set to the remote controller side, but no room temperature data is sent to the main unit for 10 minutes, the sensor is automatically switched to the indoor unit side. As much as possible, install the remote controller facing the unit.

Sensor button

Fig. 1-86

7-3. Address Switches

If you are installing more than 1 indoor unit (up to 6) in the same room, it is necessary for you to assign each unit its

own address so they each can be operated by their remote controller.1 Up to 6 indoor units can be controlled separately through the address switches. The operating control has the reception address switch and the remote controller has the transmission address switch. This function is utilized by matching the transmission and reception address switches.

Remote control

ADR

ADR

ADR

ADR

address display

 

 

 

 

Address switch

* Any address

1 2 3

1 2 3

1 2 3

positions

switch position

4 5 6

4 5 6

4 5 6

 

available

 

 

 

 

7-4. Setting the Model Code

Fig. 1-86Flap display selector switch

Make the slide switch settings in the battery compartment box of the remote controller depending on the type of indoor unit in which the wireless receiving unit is used.

7-4. Setting the Model CodeOperation mode switch

In this Single Split System Air Conditioner set the switch to “A”.

*The switch is factory set to “S” / “A”.

*Always press the reset button after switching the setting.

S K NA H C

2 Operation mode switch

1 Flap display selector switch

Fig. 1-87

1

2

S K N

S K N

S K N

U1, T1 types

K1 type

F1 type

 

 

 

 

 

A H C

A H C

A H C

Heat pump with

Heat pump without

Cooling only

Auto mode

Auto mode

 

 

 

 

 

 

1-101

Page 107
Image 107