Panasonic R410A service manual Specifications, Fig. Fig

Models: R410A

1 198
Download 198 pages 33.93 Kb
Page 97
Image 97
Manual background

(7)Suspend the indoor unit as follows.

(a)Mount a washer and two hexagonal nuts on each suspension bolt as shown in Fig. 1-58.

(b)Lift the indoor unit with a lifting machine to the ceiling surface, and place it on the washers through the notches, to fix it in place.

(Fig. 1-59)

(c)Tighten the two hexagonal nuts on each suspension bolt to suspend the indoor unit as shown in Fig. 1-60.

NOTE

A ceiling surface is not always level. Please confirm that the indoor unit is evenly suspended. For the instal- lation to be correct, leave a clearance of about 3/8" between the ceiling panel and the ceiling surface and fill the gap with an appropriate insulation or filler material.

(8)If the tubing and wiring are to go towards the rear of the unit, make holes in the wall. (Fig. 1-61)

(9)Measure the thickness of the wall from the inside to the outside and cut PVC pipe at a slight angle to fit. Insert the PVC pipe in the wall. (Fig. 1-62)

1. Specifications

Approx.

1 inch

Ceiling

surface

Washer

Nut

(supplied)

(field supply)

 

Suspension bolt

Fig. 1-58

1

Fig. 1-59

Fig. 1-60

Indoor

Outdoor

side

side

Fig. 1-61

PVC pipe (field supply)

 

OUTSIDE

INSIDE

Wall

 

 

 

 

PVC pipe

 

 

Slight

 

 

angle

Cut at slight angle

Fig. 1-62

1-91

Page 97
Image 97
Panasonic R410A service manual Specifications, Fig. Fig