Panasonic R410A service manual 1-3Other Component Specifications Outdoor Unit, 1-37, MODEL No

Models: R410A

1 198
Download 198 pages 33.93 Kb
Page 43
Image 43
U-42PE1U6, U-42PS1U6

1. Specifications

1-3 Other Component Specifications

Outdoor Unit

 

MODEL No.

 

 

 

 

U-42PE1U6, U-42PS1U6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermistor (Coil sensor) : TH2 to 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil resistance

 

k

14

°F : 23.7

,

50

°F :

9.7

 

 

 

 

 

23

°F : 18.8

,

68

°F :

6.5

 

 

 

 

 

32

°F : 15.0

,

86

°F :

4.4

 

 

 

 

 

41

°F : 12.1

,

104

°F :

3.1

 

 

 

 

 

 

 

 

 

113

°F :

2.6

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermistor (Comp. discharge gas sensor) : TH6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil resistance

 

k

140

°F : 13.8

,

194

°F :

5.1

 

 

 

 

 

158

°F :

9.7

,

212

°F :

3.8

 

 

 

 

 

167

°F :

8.2

,

230

°F :

2.8

 

 

 

 

 

176

°F :

7.0

,

248

°F :

2.2

 

 

 

 

 

185

°F :

5.9

,

266

°F :

1.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Solenoid coil or 4 way valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 way valve

 

 

 

 

STF - 04U1G

 

 

 

 

 

 

 

 

 

 

 

 

 

Solenoid coil

 

 

STF - 01AQ503UA1 (Heat pump model only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electric expansion valve (MOV)

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

Valve

 

 

 

 

UKV - 25D

 

 

 

 

Coil

 

 

 

 

UKV - U013E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE

1-37

Page 43
Image 43
Panasonic R410A 1-3Other Component Specifications Outdoor Unit, Data Subject To Change Without Notice, 1-37, MODEL No