6-4. Installing the Drain Piping

(1)Prepare standard hard PVC pipe for the drain and use the supplied drain hose and hose band to pre- vent water leaks.

The PVC pipe must be purchased separately. The transparent part allows you to check drainage. (Fig. 1-17)

Tighten the hose clamps so CAUTION their locking nuts face upward.

(Fig. 1-17)

(2)After checking the drainage, wrap the supplied packing and drain pipe insulator around the pipe. (Fig. 1-18)

 

NOTE

1

Ensure the drain pipe has a downward gradient (1/100

 

or more) and that there are no water traps.

 

 

CAUTION

Do not install an air bleeder tube, as this may cause water to spray from the drain tube outlet. (Fig. 1-19)

If it is necessary to increase the height of the drain pipe, the section directly after the connec- tion port can be raised a maximum of 19-1/2". Do not raise it any higher than 19-1/2", as this could result in water leaks. (Fig. 1-20)

Do not install the pipe with an upward gradient from the connection port. This will cause drain water to flow backwards and leak when the unit is stopped. (Fig. 1-21)

Do not apply force to the piping on the unit side when connecting the drain pipe. The pipe should not be allowed to hang unsupported from its connection to the unit. Fasten the pipe to a wall, frame, or other support as close to the unit as possible. (Fig. 1-22)

Provide insulation for any drain pipe that is run indoors.

Refer to “ SUPPLEMENT ON DRAIN PIPING”.

1. Specifications

Transparent part for

Hose band

Adhere with

checking drainage

(supplied)

PVC adhesive.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Packing

Drain hose

Drain hose

Hard PVC pipe

adapter

(not supplied)

(supplied)

(supplied)

(supplied)

 

Fig. 1-17

Drain insulator (supplied)

Fig. 1-18

Air bleeder

Fig. 1-19

11" or less (as short as possible)

19-1/2" or less

Fig. 1-20

Upward gradient prohibited

Fig. 1-21

Support pieces

Fig. 1-22

1-78

Page 84
Image 84
Panasonic R410A service manual Installing the Drain Piping

R410A specifications

Panasonic R410A is a refrigerant that has gained significant popularity in the air conditioning and refrigeration industry due to its favorable environmental properties and performance characteristics. Specifically designed to replace the harmful R22 refrigerant, which is being phased out due to its ozone-depleting potential, R410A offers a more eco-friendly alternative without compromising on efficiency or power.

One of the main features of R410A is its high energy efficiency. It operates at a higher pressure than R22, resulting in better heat transfer capabilities. This increased efficiency translates to lower energy consumption, making units using R410A more cost-effective in the long run. Additionally, R410A is known for its ability to provide excellent cooling performance even in high-temperature environments, making it suitable for a variety of applications, from residential air conditioning systems to commercial refrigeration units.

In terms of composition, R410A is a blend of two hydrofluorocarbons (HFCs), namely R32 and R125. This combination not only minimizes ozone depletion potential (ODP) but also reduces global warming potential (GWP) compared to older refrigerants. Panasonic has emphasized the importance of innovative technologies in its products, and R410A aligns perfectly with the company's commitment to developing sustainable solutions.

Panasonic also integrates advanced technologies to optimize the performance of R410A systems. For example, variable speed compressors, known as inverter technology, enhance system efficiency by adjusting the compressor's speed according to the cooling demand. This ensures that energy is only consumed when needed, further reducing operational costs.

Furthermore, R410A has a wide range of applications, including air conditioning systems, heat pumps, and chillers. Its versatility makes it a popular choice among manufacturers and consumers alike. The refrigerant is also compatible with existing R22 equipment, although specific retrofit procedures must be followed to ensure peak performance and reliability.

In conclusion, Panasonic R410A stands out as an innovative refrigerant choice in the HVAC industry, offering a combination of energy efficiency, environmentally friendly properties, and advanced technologies. As regulatory frameworks continue to tighten on greenhouse gas emissions, R410A and similar refrigerants are expected to play a crucial role in shaping a more sustainable future for air conditioning and refrigeration. Its high performance and lower environmental impact solidify its position as a leading refrigerant in contemporary cooling solutions.