How to Connect Wiring to the Terminal

WARNING Loose wiring may cause the terminal to overheat or result

in unit malfunction. A fire hazard may also exist. Therefore, ensure that all wiring is tightly connected.

When connecting each power wire to the corresponding terminal, follow the instructions on “How to connect wiring to the terminal” and fasten the wire securely with the fixing screw of the terminal plate.

How to Connect Wiring to the Terminal

 For stranded wiring For stranded wiring

(1)Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation to expose the stranded

1wiring about 3/8 in. (Fig. 1-1)

(2)Using a Phillips head screwdriver, remove the terminal screw(s) on the terminal plate.

(3)Using a ring connector fastener or pliers, securely clamp each stripped wire end with a ring pressure terminal. (Fig. 1-1)

(4)Place the ring pressure terminal, and replace and tighten the removed terminal screw using a screwdriver. (Fig. 1-2)

1. Specifications

 

Stranded wire

in.

Ring

3/8

pressure

Strip

terminal

 

Fig. 1-1

Special

Screw

 

washer

 

 

 

 

Ring pressure

Screw and

 

terminal

Special washer

Wire

Terminal plate

 

 

 

Ring pressure

Manual background terminal

Wire Manual background

Fig. 1-2