U-36PE1U6, U-36PS1U6

1. Specifications

1-3 Other Component Specifications

Outdoor Unit

 

MODEL No.

 

 

U-36PE1U6, U-36PS1U6

 

 

 

 

Thermistor (Coil sensor) : TH2 to 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil resistance

 

k

14 °F : 23.7

,

50

°F :

9.7

 

 

 

 

23 °F : 18.8

,

68

°F :

6.5

 

 

 

 

32 °F : 15.0

,

86

°F :

4.4

 

 

 

 

41 °F : 12.1

,

104

°F :

3.1

 

 

 

 

 

 

113

°F :

2.6

 

 

 

 

 

 

 

 

 

 

 

Thermistor (Comp. discharge gas sensor) : TH6

 

 

 

 

 

 

 

 

Coil resistance

k

140

°F : 13.8

,

194 °F :

5.1

 

 

 

 

158

°F :

9.7

,

212 °F :

3.8

 

 

 

 

167

°F :

8.2

,

230 °F :

2.8

 

 

 

 

176

°F :

7.0

,

248 °F :

2.2

 

 

 

 

185

°F :

5.9

,

266 °F :

1.7

 

 

 

 

 

 

 

 

 

 

 

 

Solenoid coil or 4 way valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 way valve

 

 

 

 

STF - 02U2G

 

 

 

 

 

 

 

 

 

 

 

Solenoid coil

 

 

STF - 01AQ503UA1 (Heat pump models only)

 

 

 

 

 

 

 

 

 

 

 

1

 

Electric expansion valve (MOV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve

 

 

 

 

UKV - 18D13

 

 

 

 

Coil

 

 

 

 

UKV - U013E

 

 

 

 

 

 

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE